CT-100 current sensor for poultry house fans and motors
SKU: CT-100
Clamp-on current sensor that shows whether a fan or motor is drawing current.
- Range
- AC 0.2-100 A
- Resolution
- 0.01 A
- Output
- RS485 Modbus-RTU
What the CT-100 current sensor measures on a poultry house fan or motor
The CT-100 measures the alternating current that a motor draws. It is a split-core sensor: the core opens like a clip, closes around one conductor of the motor supply cable and measures the current in that conductor through its insulation. Nothing is cut and nothing is disconnected, so the fan or pump stays wired and in service while the sensor is fitted.
It measures from 0.2 to 100 A at 50-60 Hz, in steps of 0.01 A. That range takes in the equipment of a poultry house, from a small circulation fan to a large tunnel fan, a feed auger or a well pump. Each sensor is calibrated across its range when it is made and gives a finished value in amps. The sensor is supplied with 5-24 V DC and uses 0.5 W.
On a farm the current shows, for each machine, whether it is running. A motor that is turning draws current. A motor that has tripped or burnt out draws none, whatever the switch in the panel says.
Monitoring fan current in a poultry house
Ventilation is the system a flock can least afford to lose. In a closed house full of grown birds, the fans carry away the heat the birds produce, and when they stop the house warms quickly. The climate computer knows which fans it has switched on. It does not know whether they are turning. Between the relay and the moving air there is a contactor, an overload, a cable, a motor, a belt and a set of shutters, and any of them can fail while the screen in the control room still shows the fan as on.
Temperature does show a ventilation failure, but late. The house has to heat up before a temperature probe reports anything, and on a hot day those are the minutes that count. The current of the fan falls at the moment the motor stops. Measuring it puts the fault on record at its start and names the fan, so whoever goes to the house knows which breaker to look at.
The current also shows faults that never trip anything. A fan whose belt has snapped keeps its motor spinning with almost no load, and the current settles well below its normal value. A motor with a failing bearing or a fan fouled with dust and feathers works harder, and its current creeps upward over the weeks. Neither fault changes what the climate computer displays.
A fan that trips on a hot afternoon
Picture a broiler house in the last week of the flock in summer. All the tunnel fans are running and have been since mid-morning. At three in the afternoon the overload of one fan trips, because the motor is hot and the supply voltage has sagged with every farm in the area running its fans. The house now moves less air than the climate computer believes. The birds at the far end begin to pant, and the temperature probe near the middle of the house rises slowly.
Without a current reading, the grower learns about it when the high temperature alarm goes, or on the next walk through the house. With a CT-100 on each fan, the record shows one fan at zero amps while its neighbours draw their normal current. The fault is known while it is still one fan and one reset button, and the grower can judge from the remaining fans how fast to get there.
The same reading is useful after the event. A fan that trips on three hot afternoons in a row has a cause: a tired motor, a tight bearing, a loose terminal. The current record shows the pattern, and the fan can be repaired in the cool of the morning before it fails for good.
Feed line motors, water pumps and other equipment worth a clamp
Any motor on the farm that the birds depend on can carry a sensor. These are the ones growers fit first.
- Minimum ventilation fans: the few fans that run in cycles through a cold night, when a failure lets ammonia and moisture build up in a closed house.
- Tunnel fans: the fans that stand between the flock and heat stress in summer.
- Feed auger and feed line motors: a motor that never starts leaves the pans empty, and a motor that runs without stopping usually means an empty silo, a bridged cone or a failed level switch at the end of the line.
- The well or pressure pump: a pump that stops cuts the water of every house it supplies, and a pump that runs dry draws less current than one that is lifting water.
- The cooling pad pump: a pump that fails on a hot day leaves the pads dry while the fans go on pulling hot air through them.
- Egg belts, manure belts and heater blowers: a stop that goes unnoticed on any of them costs a morning of work.
Fitting the clamp around one conductor of the motor cable
The sensor clamps around one conductor only. This is the point that is most often got wrong. A motor cable carries the current out on one conductor and back on another, and if the core closes around the whole cable the two cancel and the reading falls close to zero. The core has to go around a single insulated conductor, live or neutral, which in practice means fitting it inside the panel or the junction box, where the conductors are separated. On a three-phase motor it goes around one of the three phase conductors.
Press the catch, open the core, place it around the conductor and close it until the catch clicks. The two faces of the core must meet flush, because a gap between them lowers the reading. Keep the faces clean, since grit between them has the same effect. The sensor has a 1 m signal cable with four wires. Route it away from the motor cables, cross power runs at a right angle where it has to cross them, and leave it slack so the sensor does not hang on its cable.
The housing is ABS and the sensor works from -20 to 70 °C, which covers a fan panel in summer. The core clamps onto insulated cable only. Work inside a panel or on a live circuit is for a qualified electrician, under the electrical regulations that apply on your farm.
Which fans and motors to monitor first
One sensor watches one motor. A house with many fans does not need a sensor on every one from the first day, and most growers start with the machines whose failure hurts soonest. The minimum ventilation fans come first, since they run all year and the house has no spare for them at night. The first stage of tunnel fans comes next, then the feed line motors and the pump that supplies the house with water.
Where several fans start together from one contactor, a single sensor on the common supply shows whether the group is running, and the total current drops by a step when one fan of the group stops. A sensor on each fan names the fan directly. The choice depends on how far the panel is from the house and how quickly someone can reach it.
Check the motor nameplate before ordering. The rated current has to lie between 0.2 and 100 A, and very small motors that draw less than 0.2 A are below the range. Extended ranges can be supplied to order for larger loads. Send us the list of motors with their rated currents and we will match the sensors to them.
Checking the motor current reading after installation
After fitting, start each motor by hand and note the current it draws at normal load. That figure is the reference for the motor. A clamp meter on the same conductor should agree with the sensor, and it takes a minute to compare the two. If the sensor reads near zero with the motor running, the core is around more than one conductor or is not fully closed.
Write the normal current of each fan next to its name. From then on the reading has three plain meanings. At the normal value the fan is working. At zero the motor has stopped. A value well below normal means the motor is turning without its load, which usually points to the belt. A slow rise over the months is a reason to clean the fan and look at the bearings at the next turnaround.
There is little to maintain. When the panel is opened for other work, look at the clamp, make sure the catch is still closed and that the cable has not been pulled tight.
- Measures
- AC current on one conductor
- Range
- AC 0.2-100 A
- Resolution
- 0.01 A
- Frequency
- 50-60 Hz
- Sensing principle
- Split core, clamp-on
- Output
- RS485 Modbus-RTU
- Supply
- 5-24 V DC
- Power
- 0.5 W
- Cable
- 4-wire, 1 m standard
- Material
- ABS
- Mounting
- Snap-fit split core
- Operating temperature
- -20 to 70 °C
Where it goes
Open the core, place it around one insulated conductor of the motor supply, live or neutral, and close it until the catch clicks. Around two or more conductors of the same circuit the reading falls close to zero. Work inside a panel or on a live circuit is for qualified personnel; the sensor connects to the Genesis controller over RS485 and runs on 5-24 V DC.
What the reading does in Henlytics
- Phone alert when a fan or motor stops, repeated until acknowledged
- Current history per motor
- Fan status beside the air readings of the same house
How is the CT-100 fitted to a fan?
The split core opens, clips around one conductor of the existing cable and closes again. Nothing is cut or disconnected.
Which equipment can a CT-100 monitor?
AC loads that draw 0.2 to 100 A at 50-60 Hz, such as fan motors, pumps and feed-line motors. Check the reading against a known load when commissioning.
How many current sensors can one controller read?
Several: each CT-100 has its own Modbus address, and they share one RS485 bus on a Genesis controller with the other sensors of the house.
Tell us the houses, we will pick the sensors
Send the number of houses, the birds and what you want to watch. You get a proposed set of sensors per house and a quote, with the datasheets.