Skip to main content

Poultry house cooling monitoring for hot weather

The Henlytics heat and cooling kit is a controller and sensors that monitor how a poultry house cools in hot weather. It measures temperature and humidity before and after the cooling pad, the current of the tunnel fans and the pad pump, and CO2.

  • Before and after the cooling pad on one chart
  • Tunnel fan and pad pump current
  • Works alongside any climate controller

What the kit shows on a hot day

The air before and after the cooling pad

One temperature and humidity probe reads the air before the pad and another reads it after, and both appear on one chart.

A tunnel fan or pad pump that stopped

Current sensors on the tunnel fans and the pad pump report a motor that is switched on and drawing no current.

CO2 as a check on ventilation

CO2 rises when the house moves less air than the birds need, so its reading is an independent check on the ventilation.

What is in the heat and cooling kit

Quantities depend on the house and on its fans and pads, so the kit is quoted per house.

Genesis controller, a wall-mounted enclosure with four sensor ports along the bottom

Genesis

Four-port controller

Reads the sensors and sends the readings over the cellular network.

Sensor ports
4 modular ports, cloud-configurable
Connectivity
4G-LTE cellular, Wi-Fi 2.4 GHz, Bluetooth 5.0
Battery
Dual 18650 Li-ion, rechargeable
THS-100 temperature and humidity probes in several housings

THS-100

Temperature and humidity sensor

One probe before the cooling pad and one after it.

Temperature
-40 to +80 °C, ±0.3 °C (at 25 °C)
Humidity
0-100% RH (non-condensing), ±3% RH (at 60% RH, 25 °C)
Output
RS485 Modbus-RTU
CT-100 split-core current sensor with its core closed and a signal cable

CT-100

Current sensor

Measures the current of the tunnel fans and the pad pump.

Range
AC 0.2-100 A
Resolution
0.01 A
Output
RS485 Modbus-RTU
GF-201-CO2 fixed carbon dioxide detector with a display and a sensing head

GF-201-CO2

CO2 detector

Measures CO2 as a check on ventilation.

Range
0-5000 ppm (0-1000 ppm, 0-2000 ppm, 0-20 %VOL on request)
Resolution
1 ppm
Output
RS485 Modbus-RTU, 4-20 mA

Questions farmers ask

How do I know whether the cooling pad is working?

A THS-100 probe before the cooling pad and one after it put the two temperature and humidity readings on one chart. A current sensor on the pad pump shows whether the pump is running.

Does the kit connect to my climate controller?

The kit works alongside any climate controller and does not need to connect to it. The controller keeps running the fans and the pad, and the kit measures the result independently.

How many sensors does a house need for cooling monitoring?

It depends on the size of the house and on the number of tunnel fans, pads and pumps. Tell us about the house and the kit is sized and quoted for it.

Get the kit sized before the hot season

Send the size of the house and the number of tunnel fans, pads and pumps. You get a sized kit and a quote, with the datasheets.